For best results, read all instructions before attempting setting this up on your AquaPlus Heat Pump
The timer allows up to three separate on/off periods per day (within a 24-hour period).
All three timer periods must be set for the timer function to operate.
-
From the main controller display, press and hold the Clock key for 3 seconds to enter the timer settings.
-
The screen will display Timer 1, with the hour field flashing.
-
Press the Clock key to select the hour field.
-
Use the Up and Down keys to set the desired start hour.
-
-
Press the Clock key to move to the minute field.
-
Use the Up and Down keys to set the desired start minutes.
-
-
Press the Clock key to set the end time for Timer 1.
-
Set the end hour, then press the Clock key.
-
Set the end minutes, then press the Clock key to confirm.
-
-
After completing Timer 1, the controller will automatically move to Timer 2 and Timer 3.
-
Repeat the same steps to configure these periods.
-
-
If a timer period is not required, set the start time and end time to the same value.
-
This will effectively disable that period, while still allowing the timer function to operate correctly.
-